Thứ Hai, 14 tháng 10, 2013

Fluke 190-102

CÔNG TY TNHH THƯƠNG MẠI DỊCH VỤ CÔNG NGHỆ TK
Hotline: 094 777 888 4. Email:info@thietbi.us iWebsite: tktech.vnthietbido.us ,thietbi.us
Đ/C: 49/6M Quang Trung, Phường 8, Q. Gò Vấp, Tp. Hồ Chí Minh
Tel: 08. 668 357 66 - 08. 54273948 . Fax: 08.3984 8627
STK: 118157119 - CTy TNHH Thương Mại Dịch Vụ Công Nghệ TK - PGD Tô Ký
Liên hệ: Mr. Đến - 091 882 0407 - phden.tk@gmail.com

Fluke 190-102 

Fluke 190-102 ScopeMeter® Test Tool
Fluke 190-102
Fluke 190-102
Color ScopeMeter, 100 MHz, 2 channels plus DMM/Ext.input

Thông số kỹ thuật Fluke 190-102

BandwidthFluke 190-502: 500 MHz
Fluke 190-204: 200 MHz
Fluke 190-202: 200 MHz
Fluke 190-104: 100 MHz
Fluke 190-102: 100 MHz
Fluke 190-062: 60 MHz
Number of ChannelsFluke 190-502: 500 MHz: 2 channels
Fluke 190-204: 200 MHz: 4 channels
Fluke 190-202: 200 MHz: 2 channels
Fluke 190-104: 100 MHz: 4 channels
Fluke 190-102: 100 MHz: 2 channels
Fluke 190-062: 60 MHz: 2 channels
Real-time sample rateFluke 190-502: 5 GS
Fluke 190-204: 2.5 GS/s
Fluke 190-202: 2.5 GS/s
Fluke 190-104: 1.25 GS/s
Fluke 190-102: 1.25 GS/s
Fluke 190-062: 625 MS/s
Inputs4 scope or 2 scope plus DMM input
Independently floating isolated inputsUp to 1000 V CAT III/600 V CAT IV between inputs, references and ground
Timebase range2 ns – 2 min/div (190-20X, 200 MHz models)5 ns – 2 min/div (190-10X, 100 MHz models)10 ns – 2 min/div (190-062, 60 MHz model)
Input sensitivity2 mV-100 V/div
Trigger typesConnect-and-View™, Free Run, Single Shot, Edge, Delay, Dual Slope, Video, Video Line, Selectable pulse width, N-Cycle
Trigger SourceAny scope input channel, or external via DMM input on 190-XX2, 2 channel models
Glitch capture8 ns
Scope measurementsCursor: 7
Automatic: 30
Maximum record lengthScopeRecord mode: 30,000 pts
Scope mode: 10,000 pts per input
PersistenceDigital persistence giving analog oscilloscope-like waveform decay
Waveform CompareWaveform reference with automatic Pass/Fail testing
DMM Specification (2-channel models)
Meter inputs (also used as External Trigger Input for the Oscilloscope Mode)4 mm banana inputs, fully isolated from scope inputs and from scope ground
Maximum Resolution:5000 counts
Measurements:Vdc, Vac rms, Vac+dc rms, Resistance, Continuity, Diode Test, Current (through clamp or shunt), Temperature ºC or ºF (using optional converter)
Memory190-XX2, 2 Channel
Screen + Setup: 30
Recording: 10
Display153 mm full color LCD with fast update rate
Environmental Specifications
Operating Temperature0ºC to 40ºC Including Batteries
0ºC to 50ºC Excluding BatteriesStorage Temperature -20°C to +60°COperating AltitudeUp to 2,000 m (6666 ft) for CAT IV 600 V, CAT III 1000 V
Up to 3,000 m (10,000 ft) for CAT III 600 V, CAT II 1000 V
Fluke 190-102
Safety Specifications
Electrical Safety1,000V CAT III/600V CAT IV (EN61010-1)
Mechanical & General Specifications
Size270 x 190 x 70 mm
Weight2.2 kg
Warranty3-years on main instrument, 1-year on accessories
Li-Ion Battery190-XX2, 2 Channel models 190 BP291 4800 mAh battery up to 7 Hours included standard
Included Accessories
Two channel modelsVPS410 Voltage Probe Sets (one red, one blue)
TL175 TwistGuard™ safety designed Test Lead Set (red and black)
BC190 Battery Charger/mains Adapter
BP290 2400 mAh Li-ion Battery
Handstrap (affixed to instrument)
Hangstrap
Multi-Language User Manuals on CD-Rom
FlukeView ScopeMeter demo package (restricted functionality)
USB Interface Cable
Four channel modelsVPS410 Voltage Probe Sets (one red, one blue, one grey, one green)
BC190 Battery Charger/mains Adapter
BP291 4800 mAh high capacity Li-ion Battery
Handstrap (affixed to instrument)
Hangstrap
Multi-Language User Manuals on CD-Rom
FlukeView ScopeMeter demo package (restricted functionality)
USB Interface Cable
TKTECH.VN Cung cấp Fluke 190-102
Tìm với google Fluke 190-102
  • Fluke 190-102

Không có nhận xét nào:

Đăng nhận xét