Thứ Sáu, 4 tháng 10, 2013

Ampe kìm Fluke 353

Ampe kìm Fluke 353

Ampe kìm Fluke 353
Ampe kìm Fluke 353

Ampe kìm Fluke 353

Versatile and rugged tools for applications with high currents Confidently take reliable readings with the True-rms, Fluke 355 and 353 digital clamp meters; the tools of choice for high current clamp-on amp meter measurement up to 2000 A. The extra-wide jaw easily clamps around large conductors, typically found in high-current applications. The extra rugged design and CAT IV 600 V, CAT III 1000 V ratings add an extra element of user protection when taking high-powered measurements. Accurate peak measurements can be taken using the in-rush current mode, ideal for motors and inductive loads. The 355 also measures voltage and resistance, making this an ideal clamp meter for utilities, electrical contractors and industrial service technicians.
Ampe kìm Fluke 353
Ampe kìm Fluke 353
  • Fuatures

  • Reliably handle a wide range of high-current applications with 2000 A ac + dc true-rms, 1400 A ac, and 2000 A dc
  • The large 58 mm (2.3 in) jaw capacity is suitable for large or multiple conductors
  • CAT IV 600 V, CAT III 1000 V rating for added user protection
  • In-rush current measurement captures ‘power-on’ surge current with accuracy and repeatability
  • High voltage measurement of 1000 V ac + dc true-rms, 600 V ac, and 1000 V dc allows the user to perform multiple tests with only one tool (355 only)
  • Resistance to 400K ohms coupled with a continuity beeper provide the convenience of a multimeter in a clamp meter. (355 only)
  • Accurately measure frequency up to 1 kHz for optimum troubleshooting
  • Quickly analyze readings using the MIN, MAX, and AVG functions
  • A large backlit display allows for easy visibility in low-lit areas
  • Use the display hold feature to capture readings even when the display cannot be viewed
  • Use the low-pass filter to smooth out noisy loads and stabilize readings

Electrical specifications
Current measurement dc and ac 10 Hz to 100 Hz
Range : 40 A Resolution: 10 mA Accuracy, A: 1.5 % rdg + 15 digits Trigger Level for Inrush: 0.50 A Trigger Level for Hz Filter OFF: 2.50 A Trigger Level for Hz Filter ON: 0.50 A
Range : 400 A Resolution: 100 mA Accuracy, A: 1.5 % rdg + 5 digits Trigger Level for Inrush: 5.0 A Trigger Level for Hz Filter OFF: 2.5 A Trigger Level for Hz Filter ON: 2.5 A
Range : 2000 A; 1400 ac rms Resolution: 1 A Accuracy, A: 1.5 % rdg + 5 digits Trigger Level for Inrush: 5 A Trigger Level for Hz Filter OFF: 8 A Trigger Level for Hz Filter ON: 8 A
Crest Factor (50/60 Hz)
Range : 40 A Crest Factor* : 2 @ 33 A, 2.4 @ 27 A
Range : 400 A Crest Factor* : 2 @ 330 A, 2.4 @ 270 A
Range : 2000 A; 1400 ac rms Crest Factor* : 2 @ 1000 A, 2.4 @ 833 A
Current measurement ac 100.1 Hz to 1 kHz
Range : 40 A Resolution: 10 mA Accuracy > 10 A : 3.5 % rdg + 15 digits Trigger Level for Inrush: 0.50 A Trigger Level for Hz Filter OFF : 2.50 A Trigger Level for Hz Filter ON : 0.50 A
Range : 400 A Resolution: 100 mA Accuracy > 10 A : 3.5 % rdg + 5 digits Trigger Level for Inrush: 5.0 A Trigger Level for Hz Filter OFF : 2.5 A Trigger Level for Hz Filter ON : 2.5 A
Range : 2000 A; 1400 ac rms Resolution: 1 A Accuracy > 10 A : 3.5 % rdg + 5 digits Trigger Level for Inrush: 5 A Trigger Level for Hz Filter OFF : 8 A Trigger Level for Hz Filter ON : 8 A
Voltage measurement (355 only) dc and ac 10 Hz to 100 Hz (600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.)
Range : 4 V Resolution: 1 mV Accuracy: 1 % rdg + 10 digits Trigger Level for Hz Filter OFF: 0.050 V Trigger Level for Hz Filter ON: 0.050 V
Range : 40 V Resolution: 10 mV Accuracy: 1 % rdg + 5 digits Trigger Level for Hz Filter OFF: 0.25 V Trigger Level for Hz Filter ON: 0.25 V
Range : 400 V Resolution: 100 mV Accuracy: 1 % rdg + 5 digits Trigger Level for Hz Filter OFF: 6 V Trigger Level for Hz Filter ON: 6 V
Range : 600 V ac rms Resolution: 1 V Accuracy: 1 % rdg + 5 digits Trigger Level for Hz Filter OFF: 6 V Trigger Level for Hz Filter ON: 6 V
Range : 1000 V dc Resolution: 1 V Accuracy: 1 % rdg + 5 digits
Voltage measurement (355 only) ac 100.1 Hz to 1 kHz (600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.)
Range: 4 V Resolution: 1 mV Accuracy: 3 % rdg + 10 digits Trigger Level for Hz Filter OFF: 0.050 V Trigger Level for Hz Filter ON: 0.050 V
Range: 40 V Resolution: 10 mV Accuracy: 3 % rdg + 5 digits Trigger Level for Hz Filter OFF: 0.25 V Trigger Level for Hz Filter ON: 0.25 V
Range: 400 V Resolution: 100 mV Accuracy: 3 % rdg + 5 digits Trigger Level for Hz Filter OFF: 6 V Trigger Level for Hz Filter ON: 6 V
Range: 600 V ac rms Resolution: 1 V Accuracy: 3 % rdg + 5 digits Trigger Level for Hz Filter OFF: 6 V Trigger Level for Hz Filter ON: 6 V
Ohms measurement (355 only)
Range: 400 Ω Resolution: 0.1 Ω Accuracy: 1.5 % + 5 digits
Range: 4 kΩ Resolution: 1 Ω Accuracy: 1.5 % + 5 digits
Range: 40 kΩ Resolution: 10 Ω Accuracy: 1.5 % + 5 digits
Range: 400 kΩ Resolution: 100 Ω Accuracy: 1.5 % + 5 digits
Continuity beeper (355 only)
 On at ≤ 30 Ω
 Off at ≥ 100 Ω
Frequency measurement
Measurement range 5.0 Hz to 1 kHz
Resolution 0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz)
Accuracy – 5.0 Hz to 100 Hz 0.2 % + 2 counts
Accuracy – 100.1 Hz to 1 kHz 0.5 % + 5 counts
Trigger level Refer to current and voltage tables
*Add 2 % to error spec for CF > 2
General specifications
Batteries
 Six 1.5 V AA NEDA 15 A or IEC LR6
Battery life (with typical usage, backlight off)
 100 hours
Test leads
 Rated to 1000 V
Weight
 .814 kg (1.8 lb)
Jaw size
 58 mm (2.28 in)
Dimensions (LxWxD)
 300 mm x 98 mm x 52 mm (12 in x 3.75 in x 2 in)
Safety rating
 IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III
Environmental specifications
Operating temperature
 32 °F to + 122 °F (0 °C to +50 °C)
Storage temperature
 -4 °F to 140 °F (-20 °C to +60 °C)
Operating humidity
 0 to 95 % (non-condensing)
Operating altitude
 2000 m
Storage altitude
 10,000 m
IP rating
 42 (indoor use only)
Drop test requirements
 1 m
EMI, RFI, EMC
 FCC part 15, IEC/EN 61326-1:1997 class B, IEC/EN 61326:1997 3V/m, performance criteria B, EN61325
Temperature coefficients
Current: 0.1 % of reading per °C outside 22 °C to 24 °C
Voltage: 0.1 % of reading per °C outside 22 °C to 24 °C

Phụ kiện của Ampe kìm Flkue 353

Model NameDescription
Fluke 355AC/DC TRMS CLAMP METER,2000AIncludes:
  • 355 clamp meter
  • C43 Soft carrying case
  • 6 AA batteries
  • TL224 1.5 m silicone rubber test leads
  • TP2 Test Probes
  • AC285 Alligator Clips
  • User manual
  • 1 year warranty

Fluke 353AC/DC TRMS CLAMP METER,2000A,AMPS ONLYIncludes:
  • 353 clamp meter
  • C43 Soft carrying case
  • 6 AA batteries
  • User manual
  • 1 year warranty

Tìm với google Ampe kìm FLuke 353:
  • Ampe kìm FLuke 353,
  • Ampe kìm,
  • FLuke 353,
  • Clamp meter,
  • Fluke 353 True-rms 2000 A Clamp Meters
  • Ampe kìm Fluke 353


Nguồn: http://thietbido.us/fluke/ampe-kim-fluke-353/#ixzz2goUUgPEh
Follow us: @congnghetk on Twitter | tktech.vn on Facebook

Không có nhận xét nào:

Đăng nhận xét